Description: Electronic personal dosimeter (EPD). May be used for legal Dose of Record determination if NVLAP accredited.
DIQCode: [D,Q]
[Note: This item was previously numbered as 07RD-01-DOSE.]


ImportantFeatures: Auto range (μR to mR to R)/hour (SI Units also available).
Small, lightweight.
Beta/Gamma detection and quantification.
Neutron detection option available, no quantification.
Various alarm modes (audible, visible, vibrating).
Capability to set alarm thresholds.


Operating Considerations: May be used for legal Dose of Record determination if NVLAP accredited.
Check manufacturer specifications regarding calibration - in some cases, routine maintenance, even battery change, may require recalibration.
Limited battery life.
Limited sensitivity.
ICostRating: $
MCostRating: $


Training Requirements: Core Training: NFPA 470 Chapter 8 or Chapter 10.
Initial Training: Minimal (<1 day)
Sustainment Training: Minimal (<1 day)


Mandatory Standards:

Applicable Standards and References:


MSSL:
  • HazMat: Response Team
  • Bomb Squad
  • Maritime
  • Preventive Rad/Nuc Detection
  • Law Enforcement: SWAT/Tactical Team
  • REL: Full Canadian Recommended Equipment List
  • REL: LOS-1, Multi-Agency Intervention
  • REL: LOS-2, Scout/Reconnaissance Mission
  • REL: LOS-3, Suspicious Powder Response