Description: Self-reading personal dosimeter (SRD) or pocket ionization chambers (PIC). Not to be used for determining legal Dose of Record.
DIQCode: [D,Q]


ImportantFeatures: Records and displays total dose of wearer.
Detects Gamma only.
May be colorimetric cards or bubble technology.


Operating Considerations: Used to estimate total exposure from a specific incident. Not a substitute for personal dosimeters used in formal radiation monitoring programs. Not used to determine dose of record.
Shock sensitive.
Charging unit [battery operated & non-battery (piezoelectric)].
Some models can be difficult to read (e.g., low ambient light may make it difficult to discern colors on colorimetric cards).
Does not alarm - requires reading/interpretation by wearer.
ICostRating: $
MCostRating: $


Training Requirements: Core Training: NFPA 470 Chapter 4.
Initial Training: Minimal (<1 day)
Sustainment Training: Minimal (<1 day)


Mandatory Standards:

Applicable Standards and References:


MSSL:
  • HazMat: Response Team
  • Law Enforcement: Bomb Squad
  • Law Enforcement: Maritime
  • Law Enforcement: Preventive Rad/Nuc Detection
  • Law Enforcement: SWAT/Tactical Team
  • REL: Full Canadian Recommended Equipment List
  • REL: LOS-1, Multi-Agency Intervention
  • REL: LOS-2, Scout/Reconnaissance Mission
  • REL: LOS-3, Suspicious Powder Response