IAB Interactive Standardized Equipment List   return to main tree

Search Interactive SEL:



SEL Number: 01PF-01-SHRD
Title: Shroud, Protective, Proximity Fire Fighting, NFPA 1971


Last Updated: 7/8/2022 12:41:53 PM

Previous SEL Number: 01PF-01-SHRD

Description: Proximity fire fighting protective shroud (certified as compliant with NFPA 1971).

ImportantFeatures: A proximity protective fire fighting shroud is a protective interface component that extends from the helmet to provide protection to the face and neck area not protected by other items. The shroud features the same three-layer construction provided in the clothing to offer a similar level of radiant heat protection.

Operating Considerations: Proximity fire fighting is a specialized fire fighting operation that can include the activities of rescue, fire suppression, and property conservation at incidents involving fires producing high levels of radiant, conductive, and convective heat. Specialized thermal protection is necessary for persons involved in such operations due to the scope of these operations and the proximity to the fire (although direct entry into flame is NOT made). These are usually exterior operations, but may be combined with interior operations. Proximity fire fighting is not structural fire fighting but may be combined with structural fire fighting operations. Proximity fire fighting also is not entry fire fighting. Structural fire fighting protective clothing does not protect against chemical agents or toxic industrial chemicals. The shroud should be selected to be compatible with the helmet, coat, and other elements of the proximity fire fighting protective ensemble.

Use considerations are provided in OSHA Title 29 CFR Section 1910.132 and NFPA 1500, Standard on Fire Department Occupational Safety and Health Program. Selection, care, and maintenance requirements are provided in NFPA 1851, Standard on Selection, Care, and Maintenance of Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting.


Training Requirements: Core Training: NFPA 1851, NFPA 470 Chapters 6 and 8 as applicable, OSHA 1910.132.
Initial Training: Moderate (1-2 days)
Sustainment Training: Moderate (1-2 days)


Mandatory Standards:


Applicable Standards and References: