Standard SEL
Interactive SEL
Canadian REL
IAB Interactive Standardized Equipment List
return to main tree
Search Interactive SEL:
[01PF-01-GLOV] Prev
[01PF-01-SHRD] Next
SEL Number:
01PF-01-HLMT
Title:
Helmet, Protective, Proximity Fire Fighting, NFPA 1971
Click here to check for SAVER documents related to this item.
Last Updated:
7/8/2022 12:41:55 PM
Previous SEL Number:
01PF-01-HLMT
Description:
Proximity fire fighting protective helmet (certified as compliant with
NFPA
National Fire Protection Association
1971).
ImportantFeatures:
Proximity fire fighting protective helmets are generally structural fire fighting protective helmets that incorporate an aluminized outer shell cover. Proximity helmets may also use a gold Mylar face shield that also affords protection from radiant heat to the face area.
Operating Considerations:
Proximity fire fighting is a specialized fire fighting operation that can include the activities of rescue, fire suppression, and property conservation at incidents involving fires producing high levels of radiant, conductive, and convective heat. Specialized thermal protection is necessary for persons involved in such operations due to the scope of these operations and the proximity to the fire (although direct entry into flame is NOT made). These are usually exterior operations, but may be combined with interior operations. Proximity fire fighting is not structural fire fighting but may be combined with structural fire fighting operations. Proximity fire fighting also is not entry fire fighting. Structural fire fighting protective clothing does not protect against chemical agents or toxic industrial chemicals. Helmets should be selected so that they are compatible with and fit together with selected
SCBA
Self Contained Breathing Apparatus
facepieces, shrouds, and garments.
Use considerations are provided in OSHA Title 29
CFR
Code of Federal Regulations
Section 1910.132 and
NFPA
National Fire Protection Association
1500, Standard on Fire Department Occupational Safety and Health Program. Selection, care, and maintenance requirements are provided in
NFPA
National Fire Protection Association
1851, Standard on Selection, Care, and Maintenance of Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting.
Training Requirements:
Core Training:
NFPA
National Fire Protection Association
1851,
NFPA
National Fire Protection Association
470 Chapters 6 and 8 as applicable, OSHA 1910.132.
Initial Training: Moderate (1-2 days)
Sustainment Training: Moderate (1-2 days)
Mandatory Standards:
NFPA 1971: Standard on Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting, 2018 Edition (planned for incorporation into NFPA 1970)
Applicable Standards and References:
29 CFR 1910. 132 (OSHA), General Requirements
NFPA 470, Hazardous Materials/Weapons of Mass Destruction (WMD) Standard for Responders, 2022 Edition
NFPA 1550: Standard for Emergency Responder Health and Safety, 2024 Edition
NFPA 1851: Standard on Selection, Care, and Maintenance of Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting, 2020 Edition (planned for incorporation into NFPA 1850)
NIOSH Publication No. 2008-132, Guidance on Emergency Responder Personal Protective Equipment (PPE) for Response to CBRN Terrorism Incidents, June 2008