Standard SEL
Interactive SEL
Canadian REL
IAB Interactive Standardized Equipment List
return to main tree
Search Interactive SEL:
[07CD-01-DOGS] Prev
[07CD-01-DPFP] Next
SEL Number:
07CD-01-DPFI
Title:
Detector, Flame Ionization (FID), Point, VOC
Click here to check for SAVER documents related to this item.
Last Updated:
6/23/2022 3:13:13 PM
Previous SEL Number:
07CD-01-DPFI
Description:
Flame ionization detector (FID) for point detection of volatile organic compounds (VOC).
DIQCode: [D]
ImportantFeatures:
Handheld.
Operating Considerations:
Check safety rating before for use in explosive atmospheres.
Non-specific, general sensing for any organic compounds in air.
Presence/absence with high sensitivity and repeatability.
Typically fueled with ultra-high-purity hydrogen (transportation may be an issue).
ICostRating: $$
MCostRating: $
Training Requirements:
Core Training:
NFPA
National Fire Protection Association
470 Chapter 8 or Chapter 10.
Initial Training: Minimal (<1 day)
Sustainment Training: Minimal (<1 day)
Mandatory Standards:
Applicable Standards and References:
ASTM E2852-13(2021) Standard Guide for Acquisition, Maintenance, Storage, and Use of Hazardous Material Detection Instrumentation
ASTM E2885-21 Standard Specification for Handheld Point Chemical Vapor Detectors (HPCVD) for Homeland Security Applications
NFPA 470, Hazardous Materials/Weapons of Mass Destruction (WMD) Standard for Responders, 2022 Edition
NFPA 475: Recommended Practice for Organizing, Managing, and Sustaining a Hazardous Materials/Weapons of Mass Destruction Response Program, 2022 Edition
MSSL:
HazMat: Response Team
REL: Full Canadian Recommended Equipment List
REL: LOS-1, Multi-Agency Intervention
REL: LOS-2, Scout/Reconnaissance Mission
REL: LOS-3, Suspicious Powder Response