Standard SEL
Interactive SEL
Canadian REL
IAB Interactive Standardized Equipment List
return to main tree
Search Interactive SEL:
[06CP-02-BRDG] Prev
[06CP-03-ICOM] Next
SEL Number:
06CP-03-BAMP
Title:
Amplifiers, Bi-directional
Click here to check for SAVER documents related to this item.
Last Updated:
11/25/2018 8:47:44 PM
Previous SEL Number:
06CP-03-BAMP
Description:
Bi-directional amplifiers, application defined.
ImportantFeatures:
May be passive or active.
Operating Considerations:
Used to extend radio signals into/out of buildings, tunnels, underground.
Needs to be professionally engineered upon installation. Careful consideration must be given to how systems are set up. A significant knowledge of the impacted systems is required. Mistakes in configuration/installation can bring down multiple systems. There are significant use policy implications with the operation of these systems.
Consider power requirements and plan for monitoring performance.
Ensure that the device is capable of handling the desired RF Band.
Training Requirements:
Core Training: Per Manufacturer's Specifications
Initial Training: Minimal (<1 day)
Sustainment Training: Minimal (<1 day)
Mandatory Standards:
Applicable Standards and References:
MSSL:
Forensic Technician
Preventive Rad/Nuc Detection
Law Enforcement: SWAT/Tactical Team