SEL Number:
03SR-03-KMON
Title:
Kits, Confined Space Air Monitoring
Click here to check for SAVER documents related to this item.
Last Updated:
3/13/2024 2:36:02 PM
Previous SEL Number:
03SR-03-KMON
Description:
Kits (including monitor, sampling hose, filters, pumps, and accessories) that monitor the atmosphere in confined spaces to detect hazardous environments.
ImportantFeatures:
Intrinsically safe.
Detection of O2 level, %LEL, and toxic vapors/gases.
Operating Considerations:
Calibration and bump testing must be completed for accurate readings. Intrinsically safe equipment is defined as "equipment and wiring which is incapable of releasing sufficient electrical or thermal energy under normal or abnormal conditions to cause ignition of a specific hazardous atmospheric mixture in its most easily ignited concentration." (Reference: ISA-RP12.6)
Consider usability while wearing full personal protective equipment.
Training Requirements:
Core Training:
NFPA
National Fire Protection Association
2500,
NFPA
National Fire Protection Association
470 Chapters 6, 8, 10 as applicable, OSHA 1910.146.
Initial Training: Moderate (1-2 days)
Sustainment Training: Minimal (<1 day)
Mandatory Standards:
Applicable Standards and References:
29 CFR 1910. 146 (OSHA), Permit-Required Confined Spaces
NFPA 70: National Electrical Code, 2023 Edition
NFPA 470, Hazardous Materials/Weapons of Mass Destruction (WMD) Standard for Responders, 2022 Edition
NFPA 2500: Standard for Operations and Training for Technical Search and Rescue Incidents and Life Safety Rope and Equipment for Emergency Services, 2022 Edition, NFPA 1670 Requirements
UL 2075, Standard for Gas and Vapor Detectors and Sensors, Edition 2, Revised August 4, 2023
MSSL:
Maritime
Preventive Rad/Nuc Detection
Law Enforcement: SWAT/Tactical Team