Standard SEL
Interactive SEL
Canadian REL
IAB Interactive Standardized Equipment List
return to main tree
Search Interactive SEL:
[01UR-01-FTWR] Prev
[01UR-01-GLOV] Next
SEL Number:
01UR-01-GARM
Title:
Garment, Rescue and Recovery, Protective, Technical Rescue Incidents, NFPA 1951
Click here to check for SAVER documents related to this item.
Last Updated:
7/8/2022 1:53:18 PM
Previous SEL Number:
01UR-01-GARM
Description:
Rescue and recovery protective ensemble garment (certified as compliant with
NFPA
National Fire Protection Association
1951).
ImportantFeatures:
Garments must cover the entire body through the combination of a coat and pants, or coverall. Garment design features will vary with the manufacturer, including the type of closure, reinforcements and pockets. Garment materials may be one or two layers. When two-layer garments are used, the outer layer will typically be the shell that provides physical and thermal protection, while the lining material provides a barrier against emergency scene liquids and potentially infectious blood and body fluids. All fabrics must be flame and heat resistant in addition to being durable and resistant to physical hazards. The barrier portions of the garment must demonstrate penetration resistance to liquid chemical and bloodborne pathogens. The overall fabric system or composite must demonstrate adequate thermal insulation for protection against accidental flash fire. The overall composite must afford a high level of breathability for long-term wearing comfort. Full garments are evaluated for liquid integrity. The level of breathability is much higher for utility garments as compared to rescue and recovery protective ensemble garments.
Operating Considerations:
This equipment is not certified to the requirements of
NFPA
National Fire Protection Association
1971, and is therefore not to be used for firefighting.
NFPA
National Fire Protection Association
1951 covers protective clothing and equipment used in technical rescue incidents that include victim search, rescue, body recovery, and site stabilization during operations, such as building/structural collapse, vehicle/person extrication, confined space entry, trench/cave-in rescue, and rope rescue. Three types of ensembles are specified: utility ensembles for operations where liquid hazards are not expected; rescue and recovery ensembles for operations involving liquid hazards; and
CBRN
Chemical, Biological, Radiological, Nuclear
ensembles that offer limited protection for first responders from vapor and liquid
CBRN
Chemical, Biological, Radiological, Nuclear
hazards.
Use considerations are provided in OSHA Title 29
CFR
Code of Federal Regulations
Section 1910.132 and
NFPA
National Fire Protection Association
1500, Standard on Fire Department Occupational Safety and Health Program.
Training Requirements:
Core Training:
NFPA
National Fire Protection Association
2500,
NFPA
National Fire Protection Association
470 Chapters 6 and 8 as applicable, OSHA 1910.120, 1910.132.
Initial Training: Moderate (1-2 days)
Sustainment Training: Moderate (1-2 days)
Mandatory Standards:
NFPA 1951: Standard on Protective Ensembles for Technical Rescue Incidents, 2020 Edition (planned for incorporation into NFPA 1950)
Applicable Standards and References:
29 CFR 1910. 120 (OSHA), Hazardous Waste Operations and Emergency Response
29 CFR 1910. 132 (OSHA), General Requirements
NFPA 470, Hazardous Materials/Weapons of Mass Destruction (WMD) Standard for Responders, 2022 Edition
NFPA 1550: Standard for Emergency Responder Health and Safety, 2024 Edition
NFPA 2500: Standard for Operations and Training for Technical Search and Rescue Incidents and Life Safety Rope and Equipment for Emergency Services, 2022 Edition, NFPA 1670 Requirements
NIOSH Publication No. 2008-132, Guidance on Emergency Responder Personal Protective Equipment (PPE) for Response to CBRN Terrorism Incidents, June 2008
MSSL:
Bomb Squad
Preventive Rad/Nuc Detection
Law Enforcement: SWAT/Tactical Team